My Quotes

Your Quote from RBA Mechanical

RBA Mechanical

rbamechanical.ca/store

160 Abbottsfield Road NW
Edmonton, AB, T5W 4S9

Customer Service:
780-474-7481
sales@rbamechanical.ca

Your Customer Details

Delivery / Job Address:

Name: ____________________________________________________

Company Name: _________________________________________

Address: _________________________________________________

___________________________________________________________

Email: ___________________________________________________

Phone: _____________________________________________


Billing Address (if different from Job address):

Name: _________________________________________________

Company Name: ______________________________________

Address: ______________________________________________

_______________________________________________________

Email: _______________________________________________

Phone: _________________________________________


Your Quote Details

Heat Exchanger for Water Heaters Serving DHW and Hydronic Heating System (open-loop)

Sku or Part #: dhw975-0708
$2,470.00
GST Extra
To convert an open loop system to closed loop. Looking for hydronic heating repair? Request a free quote.
1
Maximum purchase quantity: 1 items
Save this product for later
Heat Exchanger for Water Heaters Serving DHW and Hydronic Heating System (open-loop)
Product Details
Special Notes: For open loop systems with radiant floor heating up to 1,000 square feet where a water heater supplies both domestic hot water and radiant floor heat.
Parts and Equipment: All parts are OEM and purchased from reputable wholesalers in Edmonton
Price Includes: Supply of materials with installation
Brand: Various
Model #: LA14-30 or LA14-40

Description

Prevent the Legionella bacteria from entering your hot water supply by physically separating the domestic water from your hydronic floor heating system.

When the weather warms up, the heating demands on the hot water tank are reduced or eliminated. This causes the water in hydronic heating system to become stagnant and can grow the Legionella bacteria. This posses a very real risk to the potable water supply.

Prevent the Legionella bacteria from entering your hot water supply by physically separating the domestic water from your hydronic floor heating system. A heat exchanger is a simple device that allows heat to pass to the hydronic side of the system without the two water sources ever touching.

The Ultimate Guide to Safely Using a Water Heater for Domestic Hot Water and Hydronic Heating

This bundle package includes:

  • brazed plate heat exchanger (LA14-30 or LA14-40)
  • UPS 15-58FC recirculating pump
  • 2 gal hydronic heating expansion (bladder) tank
  • 2) whye strainers
  • 1) Pressure relief valve

This new "closed loop" system prevents cross contamination in these types of heating systems where the hot water tank is used for heating the space as well as the domestic hot water.

Installation is Included

Enhance the efficiency and reliability of your heating system with our premium Heat Exchanger for Open Loop Systems.

The necessary materials for installation are provided. This includes pipe and fittings required for the installation of the included components.

  • Expertly designed to separate domestic hot water from your hydronic heating setup, this product comes equipped with a robust circulating pump and strategically installed whye strainers on both sides to prevent blockages, ensuring seamless operation.
  • Included in this comprehensive installation is a high-quality hydronic heating bladder tank paired with an essential pressure relief valve—all components are rigorously tested to guarantee optimal performance.
  • Upon completion, we will meticulously commission your water heater back into service, allowing you to enjoy peace of mind knowing that your system operates at its best.

Elevate your home’s heating solution today with our expertly crafted heat exchanger package.

Learn More

Work Order Installation Agreement

Our work scope includes:

  • Conduct a pre-installation site visit with the customer to review the details of the project and take precise measurements
  • Supply and install a new brazed plate heat exchanger and circulating pump package, to separate the domestic hot water from the hydronic heating system.
  • Supply and install a residential hydronic bladder tank with a 30 psi pressure relief valve.
  • Test and commission the new system into service

The price does not cover the following services; however, should these services be deemed necessary during the pre-installation site inspection, they will be quoted separately or provided at an additional cost.

  • Repairs to the hydronic heating system
  • Venting alterations

Limited Warranty:
Our limited warranty is 90 days on workmanship, from the date of invoice. All parts and equipment are covered by Manufacturer’s warranty policies which may range between 6 months and 1 year. Contact us PRIOR to ordering if you have any questions about a product warranty.

Cancellations:
You have 24 hours from the time this quote is accepted to cancel this order and receive a full refund on any payments made.



ACCEPT THIS QUOTE

To Accept this Quote Offline: Complete the Customer Details portion above, choose your payment option below, and complete the bottom portion. Email your approved quote to: sales@rbamechanical.ca. We will complete the online order on your behalf.

Choose your payment option:

As an existing premium client, you may simply email your approval to proceed to sales@rbamechanical.ca. If you use purchase orders, email your PO at the same time as your approval to proceed.

_____ Pay in full now with Credit card, E-Transfer or direct deposit and get 5% discount off the total. An invoice will be emailed to you with your total payment amount due.

_____ Pay using the custom payment schedule listed in the quote. Invoices will be emailed to you a few days before payment(s) are due.

Payment instructions will be sent to you when your accepted quote is received.

_____ Pay in full now with Credit card, E-Transfer or direct deposit and get 5% discount off the total. An invoice will be emailed to you with your total payment amount due.

_____ Pay a deposit now, and the balance when our work is completed (usually 50% deposit is required). An invoice will be emailed to you with the deposit amount due.

Payment instructions will be sent to you when your accepted quote is received.

_____ Pay in full now with Credit card, E-Transfer or direct deposit and receive 5% discount. An invoice will be emailed to you with your total payment amount due.

_____ Pay the full quote amount c.o.d, when our work is completed

Payment instructions will be sent to you when we send you our invoice once our work is completed.


This quote is accepted in its entirety. I, (print name)_______________________________________________, agree to pay the payment in the manner I have chosen and authorize RBA Mechanical to complete the work as described in the description and the work order.

Signed and Accepted on (todays date) _________________________________________

Signature: _______________________________________________________________________


Why Use RBA Mechanical   |   Terms   |   Safety   |   Warranty

Our General Service Area:
Edmonton, Sherwood Park & St Albert

Request a quote outside these areas

 

Request A Quote

Please fill out the form below to request a quote and we will respond within 24 hours. If you have any questions, please contact us at 780-474-7481.